60
AnnexA Technicalspecications
TechnicalspecificationsNaturalgasG20
Boilertype UB70 UB110 UB140
Typeheatexchanger
HEX4 HEX4 HEX4
HEX2 HEX4
Input Hs CH kW
68,5 107,9 136,4
Qn Input Hi CH kW
61,8 97,3 123
Efficiency class according BED   
Rendement volgens EN677 / EN15417
(36/30°C deellast, onderw.)
% 110,2 110,3 110,2
Efficiency according EN677 / EN15417
(36/30°C part load, Hi)
% 109,8 109,2 108,9
Efficiency according EN677 / EN15417
(80/60°C full load, Hi)
% 97,3 97,6 97,6
Modulation range CH
(capacity 80/60°C)
kW 8,8 - 60,1 14,8 - 95,0 17,6 - 120,0
Modulation range CH
(capacity 50/30°C)
kW 9,9 - 65,0 16,8 - 102,3 19,8 - 130,0
Flue gas pressure Pa 175 195 195
Nox class EN483, EN15420 5 5 5
O
2
CO
2
%
%
Flue gas non-return valve present
yes yes yes
Flue gas temp. CH
(80/60°C on full load)
°C 76 73 77
Flue gas temp. CH
(50/30°C on low load)
°C 30 30 30
Gas consumption G20 CH
(at 1013 mbar/15°C)
m
3
/h
6,53 10,29 13,01
Gas category
Boiler flue category
Electr. power consumption max. W
161 250 322
Electr. power consumption part load W
44 86 88
Electr. power consumption stand by W
2,5 3,7 3,7
Current V/Hz
230/50 230/50 230/50
Degree of protection acc. EN 60529
Weight (empty) kg
65 83 87
Mounting weight kg
54 72 76
Width mm
660 660 660
Height mm
1065 1065 1065
Depth mm
460 460 460
Mounting height (excl. flue connection) mm
1715 1715 1715
Water content CH l
7 12 14
Overrun time pump CH min
3 3 3
P
MS
Water pressure min./max.
bar
0,7 / 4 0,7 / 4 0,7 / 4
Flow temperature max. °C
85 85 85
Type pump Grundfoss UPM HEX4
HEX2
GEO 25-85
-
GEO 25-85
2 25-60
GEO 25-85
GEO 25-85
CE product identification number (PIN)
TechnicalspecificationsPropanegasG31
Boilertype
UB70 UB110 UB140
Typeheatexchanger
HEX4 HEX4 HEX4
HEX2 HEX4
O
2
%
CO
2
%
Restriction plate diameter mm
5,7
-
5,7 (HEX4)
5,2 (HEX2)
5,7
5,7
Pre-pressure mbar
Load(H
i
)
kW
61,8 94,9 123
Gas consumption G31 (1015mbar, 15°C) kg/h
4,80 7,37 9,54
m
3
/h
2,52 3,87 5,01
Modulation range (80/60°C) kW
19,5-60,1 35,1-95,0 39,0-120,0
Modulation range (50/30°C) kW
22,0-65,0 39,7-102,3 44,0-130,0
5,1% (-1,2%, +0,7%)
10,3% (-0.4%, +0.8%)
see data plate propane
* EN15417 = Specific requirements for condensing boilers with a nominal heat input exceeding 70 kW up to 1000 k
W
Upsilon
II2H3P
B23 B33 C13 C33 C43 C53 C63 C83 C93
IPX4D (IPX0D for B
23
& B
33
)
4,7 (-1,2%, +0,8%)
9 (-0,4%, +0,6%)
0063CM3648
NOTE:
TheUpsilonboilerscanberunonpropane/lpg.Thelpg-gashastohaveapropane
purityofatleast90%.Whenthebutane-level is greater then 10% thewarranty
conditionsontheheatexchangersarenotvalid.
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Upsilon UB-110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Upsilon UB-110 in the language / languages: English as an attachment in your email.

The manual is 9,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Upsilon UB-110

A.O. Smith Upsilon UB-110 User Manual - English - 2 pages

A.O. Smith Upsilon UB-110 Additional guide - English, Dutch - 2 pages

A.O. Smith Upsilon UB-110 Installation Guide - Dutch - 72 pages

A.O. Smith Upsilon UB-110 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info