671771
38
Zoom out
Zoom in
Previous page
1/68
Next page
Installation and Service Manual Upsilon-Series
38
9.1 Operationalstatus
- Standby Standby. Boiler is ready for operation.
- Vent.Phase Ventilation stage
- Ignitionphase Ignition stage
- BurnerlitCH Burner active for heating
- BurnerlitDHW Burner active for hot water
- CHT>Tset Burner off on account of too high ow temperature CH
- OverrunCH Overrun time pump over CH
- OverrunDHW Overrun time pump over DHW
- Service Boiler needs maintenance. Contact installer
- Frost Burner active for frost protection
9.2 Operation
The keyboard consists of a logical key allocation for menu control, conrmation, and
correction and emission measurement.
Value increase / change
Emission measurement Return/correction
Backward Forward
Reset* Conrm selection
Value decrease / change
* Reset only functions in case of an Error or Message. If reset is rapidly pressed over a
short period of time, the device will block completely. Only loss of power (power switch)
will restart the device completely. Recommendation: First identify the fault by nding the
fault code in the fault-code list in the problem-shooting chapter and solve the problem.
The main switch is located on the right hand side of the keyboard. This switch controls
the 230V power supply (L and N).
Standby
R
OK
-
+
R
OK
-
+
0-10Volt
Open-
Therm
On/Off
T3
DHW
230V~
AC
230V
out
230V~
AC
230V
out
L
N
L
N
L
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6
Error
signal
Heat
demand
signal
LPG
On/Off
1 2 3 4 5 6 7 8 9 10 11 12 13 14
T10
General
purpose
LWCO
NN
L
230V Pump / 3-WV.
L
230V Pump P3230V out230V~ AC
T4
Out
8X.44.08.00 / 05.11
L
N
230V DHW pump
Bus
8X.44.09.00 / 05.11
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Upsilon UB-110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Upsilon UB-110 in the language / languages: English as an attachment in your email.

The manual is 9,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Upsilon UB-110

A.O. Smith Upsilon UB-110 User Manual - English - 2 pages

A.O. Smith Upsilon UB-110 Additional guide - English, Dutch - 2 pages

A.O. Smith Upsilon UB-110 Installation Guide - Dutch - 72 pages

A.O. Smith Upsilon UB-110 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info