30 Instruction manual TWI 35-130 G/TWI 45-190 G
3.10.3 Connect the mains voltage
The device is delivered without power cable and main switch.
Remark
In order to supply voltage to the device, connect the device to the mains
voltage using a permanent electrical connection. Place a double pole main
switch with a contact opening of min. 3 mm between this permanent connection
and the device. The power cable shall have a core of min. 3 x 1.0 mm².
Warning
Keep the device electrically isolated until you are ready to start it up.
1. Connect phase (L), zero (Z) and earth (
) of the power cable to the
connector (C).
2. Mount the power cable into the strain relief (D).
3. Connect the power cable to the main switch.
4. Remount the cover plate.
3.10.4 Isolating transformer
An isolating transformer is used when a ‘oating zero’ is present. Consult the
mounting instructions delivered with the isolating transformer (contact the
supplier for the correct isolating transformer).
Remark
Fill the device before starting up the device and/or checking the CO
2
-value
(5 “Fill”).
Caution
Checking the CO
2
-value is obligatory when starting up the device for the
rst time.
Remark
You obviously need a CO
2
-gauge for checking the CO
2
-value.
3
3.11 Check and
adjust the
CO
2
-value
Installation
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith TWI 35-130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith TWI 35-130 in the language / languages: English as an attachment in your email.

The manual is 2,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith TWI 35-130

A.O. Smith TWI 35-130 User Manual - German - 64 pages

A.O. Smith TWI 35-130 Usermanual and installation guide - Dutch - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info