ST 400 / 500 / 600 / 750 / 1000
24
1.5 Dimensions
Unit ST 400 ST 500 ST 600 ST 750 ST 1000
A Total height mm 1705 2040 1835 2030 2000
D Diameter tank (incl. insulation) mm 720 720 910 910 1060
M Height cold water inlet mm 70 70 85 85 95
N Height warm water outlet mm 1650 1990 1797 1992 1962
O Diameter inspection opening mm 115 115 180 180 180
P Height inspection opening mm 410 410 493 493 530
R Height connection mm 270 270 315 315 360
S Height temp. sensor connection mm 348 348 400 400 445
T Height connection mm 425 425 485 485 530
U Height recirculation connection mm 510 510 650 650 700
V Height connection mm 826 995 1040 1080 1100
W Height connection mm 1094 1348 1255 1374 1351
X Height T&P connection mm 1362 1700 1466 1662 1592
1 Cold water inlet - R 2 R 2 R 2½ R R
2 Warm water outlet - R 2 R 2 R 2½ R R
7 Recirculation connection - Rp ¾ Rp ¾ Rp ¾ Rp ¾ Rp ¾
8 Anode connection - Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼ Rp 1¼
11 Connection - Rp 2 Rp 2 Rp 2 Rp 2 Rp 2
12 Connection - Rp 2 Rp 2 Rp 2 Rp 2 Rp 2
13 Connection temp. sensor - Rp ¼ Rp ¼ Rp ¼ Rp ¼ Rp ¼
14 T&P connection - Rp 2 Rp 2 Rp 2 Rp 2 Rp 2
D
M
R
S
V
W
X
N
A
T
U
P
1
12
13
11
7
7
7
14
O
8
2
IMD-0526
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith ST 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith ST 500 in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 0,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info