503273
118
Zoom out
Zoom in
Previous page
1/126
Next page
Cable colors: Components: Controller connections:
1 Brown A Control J2 Power connection for controller
2 Blue B Flame probe J19 Extra error signal connection
3 Green C Hot surface igniter J20 Gas control valve connection
4 Black D Gas control valve J21 Program-controlled pump
connection
5 White E Burner earth connection
6 Grey/Beige F Extra ON mode switch J29 Power connection for the fan
7 Green G Program-controlled pump
(max. 100W)
J36 Controller display connection
8 Yellow J40 Regulator connection for the fan
H Extra error signal connection JP2 Flame probe and hot surface
igniter connection
Terminal strip connections: J Isolating transformer
A
Earth K Double-pole isolator JP3 Temperature sensor T
2
connection
N Neutral L Controller O/I switch
L Live input of controller M Display JP4 Dummy connection
L
1
Live input of isolating transformer
(primary side)
N Fan JP5 Temperature sensor
T
1
connection
O Temperature sensor
(T
2
- bottom of tank)
L
2
Live output of isolating
transformer (secondary side)
JP6 Selection resistor and pressure
switch connection
P Dummy
L
3
Live input of program-controlled
pump
Q Temperature sensor
(T
2
- top of tank)
JP8 Extra ON mode switch
connection
R Selection resistor
S Push button F1 Fuse (T 3.15A - 250 V)
T Electrical anodes F3 Fuse (T 3.15A - 250 V)
U Signaling for electrical anodes
V Potentiostat
W Communication between the
appliance controller and the solar
system (BUS connection)
AA Solar system controller
118 Installation, Maintenance and Service part
118


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 60 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 60

A.O. Smith SGS 60 User Manual - German - 128 pages

A.O. Smith SGS 60 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info