503271
98
Zoom out
Zoom in
Previous page
1/126
Next page
Code and description Cause Measure
S06 (blocking error)
Open circuit from
temperature sensor S
3
at
the top of the storage
tank.
Sensor is not (correctly) connected Connect the sensor lead to J14 (ports 1 and
3) of the solar controller
Damaged cable and/or defective sensor Replace the cable and/or sensor
S07 (blocking error)
Open circuit from
temperature sensor S
2
at
the bottom of the tank.
Sensor is not (correctly) connected Connect the sensor lead to J14 (ports 2 and
4) of the solar controller
Damaged cable and/or defective sensor Replace the cable and/or sensor
S08 (blocking error)
Open circuit from
temperature sensor S
1
in
the collector.
Sensor is not (correctly) connected Connect the sensor lead to J13 (ports 2 and
4) of the solar controller
Damaged cable and/or defective sensor Replace the cable and/or sensor
S11 (blocking error)
Short circuit in
temperature sensor T
2
at
the bottom of the tank.
Short circuit in sensor circuit Replace the cable and/or sensor.
S12 (blocking error)
Short circuit in sensor 1 of
temperature sensor T
1
at
top of tank
(1)
Short circuit in sensor circuit Replace the cable and/or sensor.
S13 (blocking error)
Short circuit in sensor 2 of
temperature sensor T
1
at
the top of the tank
(1)
.
Short circuit in sensor circuit Replace the cable and/or sensor.
S14 (blocking error)
Short circuit from
dummy 1
Short circuit in sensor circuit Replace the cable dummy sensor
(2)
.
S15 (blocking error)
Short circuit from
dummy 2
Short circuit in sensor circuit Replace the cable dummy sensor
(2)
.
S17 (blocking error)
Short circuit from
temperature sensor S
2
at
the bottom of the tank.
Short circuit in sensor circuit Replace the cable and/or sensor
S18 (blocking error)
Short circuit from
temperature sensor S
1
in
the collector.
Short circuit in sensor circuit Replace the cable and/or sensor
F01 (blocking error)
Defect in power supply
circuit
Live and neutral connected wrong way
around.
Be sure to
connect the live and neutral
correctly (see section 7.8); the water heater
is phase-sensitive
Condensation on the flame probe Disconnect the lead at the flame probe
Ignite the water heater three times, with
an interrupted ionisation circuit
Reconnect the ionisation lead to the
flame probe
Ignite the water heater again
The repeated ignition attempts will have
caused the condensation to evaporate
Floating neutral Install an isolating transformer (see section
7.8.3.1)
98 Installation, Maintenance and Service part
98


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 30 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 30

A.O. Smith SGS 30 User Manual - German - 128 pages

A.O. Smith SGS 30 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info