503271
75
Zoom out
Zoom in
Previous page
1/126
Next page
Fig. Gas control valve pressure adjustment
IMD-1096bR0
7.9.4 CO
2
adjustment
To check the CO
2
value under full load and partial load and to adjust it if necessary,
proceed as follows:
Isolate the appliance from the power supply (see section 4.2.2).
Carefully remove the covers from the appliance.
The electrical section is now visible.
Place the CO
2
meter's measurement probe in the test nipple (58) of the flue gas
outlet pipe (the number is a reference on the General working principle of the water
heater (see section 5.1)).
Open the gas supply and vent the gas supply line.
Use the main switch to apply mains voltage to the appliance.
Start the appliance (see section 4.1).
Go to the [ ] SERVICE OPERATION menu.
Generate a heat demand by draining the appliance until it is cold or by raising the
value for T
set
in the SERVICE menu. Use [ ]
for this.
Full load measurement
From the service menu, select:
SERVICE OPERATION | FULL LOAD
Confirm with [ENTER].
The appliance is now in FULL LOAD mode and will ignite.
The appliance is now running at FULL LOAD. Read the value from the CO
2
meter
and wait until this measured value has remained stable for some time. This may take
several minutes.
Then compare the measured CO
2
value against the value from the
table (see section
12.3).
The CO
2
value at full load must be within ±1.0 vol% of the CO
2
value stated in the
table.
SGS 28 to 60
If necessary, adjust the CO
2
value using the adjuster screw until the value is within
the range listed in the table of CO
2
values.
Use the Allen key supplied for this. The key can be found in the plastic bag that is
attached to the appliance.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
-
-
11.
12.
13.
0311753_SGS_28-120_II_UKUK_V2.0 , 2017-05-03 75
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 30 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 30

A.O. Smith SGS 30 User Manual - German - 128 pages

A.O. Smith SGS 30 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info