7.5 Gas connection
Caution
Make sure that the gas supply pipe has the correct diameter and length to supply
sufficient capacity to the water heater.
Caution
Make sure that the gas supply pipe is clean. Contamination in the pipe can cause damage
to the gas control valve, during operation.
Caution
Install the manual gas valve on a spot accessible for the user.
Install the gas connection:
Install a manual gas valve (10) in the gas supply pipe.
Make sure that the gas pipe is clean before use. If necessary, remove the
contamination from the pipe.
Close the manual gas valve.
Install the gas supply pipe to the gas control valve.
Make sure that there are no gas leaks.
7.6 Solar heating system
Note
Please refer to the installation diagram, electrical diagram and terminal block (see section
7.8.4.1)
for details of how to connect the solar heating system.
Connect the supply from the solar collector to the inlet (F) of the heat exchanger.
Connect the return pipe to the solar collector to the outlet (G) of the heat exchanger.
Connect the lead to the solar heating system controller and sensor S
2
, see:
electrical diagram and
connections table (see section 7.8.4.1).
Connect the communication cable between the solar heating system controller and
the water heater, see:
electrical diagram and
connections table (see section 7.8.4.1).
Warning
The installation diagram shows a pump station with an integrated non-return valve. This
type of pump unit may only be used with closed systems. In systems with drain-back,
installation of a pump unit with non-return valve is prohibited. There are special pump
units for these systems. Please contact the pump unit supplier for this.
7.7 Venting system
There are several alternatives for installation of the air inlet and flue gas outlet:
Installation
type
Version Description
B23 Open Air for combustion is drawn from installation room
and the flue gasses leave the water heater via a
vertical roof terminal.
C13 Closed Concentric and/or parallel venting system, with
horizontal air inlet and flue gas outlet, in same
pressure zone.
C33 Closed Concentric and/or parallel venting system, with
vertical air inlet and flue gas outlet, in same
pressure zone.
c
1.
2.
3.
4.
5.
n
1.
2.
3.
-
-
4.
-
-
w
0311753_SGS_28-120_II_UKUK_V2.0 , 2017-05-03 59
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 30 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 30

A.O. Smith SGS 30 User Manual - German - 128 pages

A.O. Smith SGS 30 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info