Code and description Cause Measure
F04 (lock out error)
Three unsuccessful
ignition attempts.
No gas Open the main gas supply valve and/or
the manual gas supply valve before the
gas control valve
Check supply pressure to the gas control
valve
If necessary, restore the gas supply
Air in the gas pipes Bleed the air out of the gas pipe (see
section 7.9.2)
and measure the supply
pressure and burner pressure.
Defect in the hot surface igniter circuit Check that the hot surface igniter is
correctly connected (JP2).
Check the wiring of the hot surface
igniter.
Measure the resistance across the hot
surface igniter. This must lie between 2
and 10 Ohm (at room temperature).
Check that the hot surface igniter lights
up during ignition.
If necessary, replace the hot surface
igniter.
Defect in the ionisation circuit Check that the flame probe is correctly
connected (JP2)
Check the wiring of the flame probe
Measure the ionisation current. This must
be a minimum of 1.5 microA.
If necessary, replace the wiring.
Supply voltage too low Check the supply voltage, this must be 230
VAC(-15%, +10%)
F05 (lock out error)
Too many flame errors
have been signaled.
Incorrect roof or wall flue terminal.
Recirculating flue gases.
Check that the correct roof or wall flue
terminal has been installed (see section
7.7)
.
If necessary, install the correct roof or
wall flue terminal.
Check that the roof or wall flue terminal
discharges into a permitted area.
F06 (blocking error)
Short circuit between
flame probe and earth
Damaged cable in contact with metal
surface or bent flame probe.
Check the wiring and the flame probe.
Replace the wiring and/or flame probe if
necessary.
Ceramic part of the flame probe is
broken/cracked.
Check whether the ceramic part of the
flame probe is still intact, in the vicinity
of the air distribution plate of the burner.
If not the flame probe must be replaced.
F07 (lock out error)
A flame has been detected
after the gas control valve
was closed.
Defective gas control valves Check whether there is still burner
pressure present, after the gas control
valves have closed.
Check whether a flame is still present,
after the gas control valves have closed.
If this is the case, the gas control valve
must be replaced.
F08 (lock out error)
Error message from safety
relay
Flame detection before the gas control
valve opened.
Reset controller.
If the error appears again, replace the
controller.
F09 (lock out error)
Water temperature
protection.
Temperature at the top of the tank
exceeds 93 ºC.
Check that the circulation pump (if
present) is working
Check the position of temperature sensor
T
1
Reset controller
100 Installation, Maintenance and Service part
100


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 100 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 100

A.O. Smith SGS 100 User Manual - German - 128 pages

A.O. Smith SGS 100 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info