9.2.5 Setting the service interval
The service interval is a feature of the controller to help the service and maintenance
engineer set the frequency of maintenance.
The service interval is determined by the number of months that the appliance has been
running. This can be set to 6, 9 and 12 months. The default service interval is 12 months.
When the preset number of months has been reached, an appropriate message will appear
(see section 3.6.3)
.
Set the service interval as follows:
[
]: SERVICE INTERVAL
To erase the message SERVICE REQUIRED, refer to Finalization (see section 10.5).
9.2.6 Service mode
The Installation engineer uses the SERVICE OPERATION menu to adjust the water heater
CO
2
setting during FULL LOAD and PARTIAL LOAD operation.
Use [ ]:SERVICE OPERATION to display the SERVICE OPERATION menu.
[ ]
and [
] can be used to switch between PARTIAL LOAD and FULL LOAD.
If there is a heat demand, the water heater will first run through a startup cycle, then
continue to operate in FULL LOAD or PARTIAL LOAD mode.
If there is no heat demand, the installation engineer must create one. This can be done by
draining the water heater until it is cold or by temporarily raising the set point using [
].
After adjustment, the set point must be set back to the original value using [ ].
if you exit the SERVICE OPERATION menu or if no buttons are pressed for a period of 15
minutes, the water heater will revert to the original operating mode.
Temporarily raising the setpoint during FULL LOAD or PARTIAL
LOAD
[ ]:>:SERVICE OPERATION.
Select FULL LOAD or PARTIAL LOAD.
The example below describes the situation for FULL LOAD, which is identical to that
for PARTIAL LOAD.
Confirm with [ENTER].
1.
2.
3.
0311753_SGS_28-120_II_UKUK_V2.0 , 2017-05-03 85
85


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 100 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 100

A.O. Smith SGS 100 User Manual - German - 128 pages

A.O. Smith SGS 100 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info