transferred to the cooler water, thereby increasing the performance of the unit. The
condensate yielded by this process is discharged via the condens trap (23).
Heat losses are prevented by the insulating layer (24) in both the storage tank and the
water heater itself. Both are enamel-coated on the inside to protect against corrosion. The
anodes (9) provide extra protection against corrosion. Both are fitted with an inspection
and cleaning opening (12) for maintenance purposes.
Fig. Water heater SGS 28, 30, 50, 60
12 5
7
4
6
28
9
11
13
12
15
24
23
22
3
58
19
29
10
8
14
16
18
20
30
21
17
18
20
17
21
30
59
16
Fig. Water heater SGS 80, 100, 120
12 5
7
4
6
28
9
11
13
12
15
24
23
22
3
58
19
29
10
8
14
16
18
20
30
21
17
1. Cover
2. Hot water outlet
3. Electrical connector block
4. Controller
5. Pressure switch
6. Control panel
7. Temperature sensor T
1
8. Combustion chamber
9. Anode
10. Tank
11. Heat exchanger
12. Inspection and cleaning
opening
13. Temperature sensor T
2
14. Cold water inlet
15. Drain valve
16. Gas control valve
17. Burner
18. Fan
19. Air supply hose
20. Hot surface igniter
21. Flame probe
22. Chimney pipe
23. Condens trap
24. Insulation layer
28. Potentiostat
29. Base
30. Venturi
58. Flue gas test point
59. Pressure-reducing valve
44 Installation, Maintenance and Service part
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 100 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 100

A.O. Smith SGS 100 User Manual - German - 128 pages

A.O. Smith SGS 100 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info