Following the post-purge, the fan stops and the pressure switch opens:
The icons and are dimmed.
The message POST PURGE vanishes.
With any subsequent heat demand, the heating cycle will resume from step 1.
4.2 Turn off the water heater
4.2.1 Turn off for a short period
To decommission the water heater for a short period, you must activate the frost
protection. The frost protection will prevent water from freezing in the water heater.
Activate the frost protection as follows:
Press [ ] to select the main menu.
Using [ ] and [ ], place the cursor beside OFF.
Confirm with [ENTER].
The frost protection cuts in when the water temperature drops below 5°C. The text FROST
will then appear on line one of the display. The water heater will heat the water to 20°C
(T
set
) before dropping back to mode OFF.
Caution
The anode protection remains active when the OFF mode
is selected.
Note
These values of 5°C and 20°C cannot be adjusted.
Note
If the water heater is not used for longer than two months and the water is not drained,
air bubbles may form in the water heater. This can lead to air in the water pipes.
4.2.2 Isolate from the mains
The water heater may only be isolated from mains power in the correct way. The correct
procedure is as follows:
Activate the MENU with [ ].
Position the cursor in front of OFF.
Confirm OFF with [ENTER].
Caution
Failure to wait until the fan stops can cause damage to the water heater.
Wait until the fan has stopped. The icon is then dimmed.
Switch the water heater OFF (position 0) using the control switch on the operator
interface.
8.
-
-
1.
2.
c
n
1.
2.
3.
c
4.
5.
0311753_SGS_28-120_II_UKUK_V2.0 , 2017-05-03 27
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGS 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGS 100 in the language / languages: English as an attachment in your email.

The manual is 5,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGS 100

A.O. Smith SGS 100 User Manual - German - 128 pages

A.O. Smith SGS 100 Usermanual and installation guide - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info