7.8.4.1 Preparation
Remove the cover (snap-on type) from the terminal block for the collector. This has the
following terminals:
7.8.4.2 Connecting the mains power
Note
Just as with the water heater controller, the solar heating system controller must have a
permanent electrical connection to the mains power supply. There must be a double-pole
isolator installed in the permanent connection. This is the same double-pole isolator as
installed between the mains power supply and the water heater itself. Whenever this
isolator is operated, both controllers can be switched on or off.
Connect earth, live and neutral to terminals 1 through 3
Fit the cables in the strain relief.
Connect the power cable to the isolator.
Continue (see section 7.8.4.3).
7.8.4.3 Connecting pump station - modulating pump
The pump station contains a modulating pump (PWM controlled). You must connect this
pump to the controller of the solar heating system.
Connect earth, live and neutral to terminals 10 through 12.
Connect PWM and PWM+ to point 1 and 2 of J18.
Fit the cables in the strain relief.
Continue (see section 7.8.4.4).
7.8.4.4 Connecting solar collector
Note
This sensor must be mounted in the solar collector;refer to the solar collector installation
manual.
Connect the sensor (S1) to the water heater as follows:
Connect the sensor to terminal 2 and 4 of J13.
Fit the cables in the strain relief.
Continue (see section 7.8.4.5).
7.8.4.5 Connecting tank sensor
Note
This sensor is already mounted in the tank prior to delivery. The sensor is mounted
between the inlet and outlet of the heat exchanger. However, you must still connect the
lead to the solar heating system controller.
Connect the lead for sensor S2 with the blade connectors to the sensor.
Connect the other end to terminals 2 and 4 of J14.
n
1.
2.
3.
4.
1.
2.
3.
4.
n
1.
2.
3.
n
1.
2.
0311732_SGE_40-60_II_UKUK_V2.0 , 2017-05-03 67
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith SGE 60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith SGE 60 in the language / languages: English as an attachment in your email.

The manual is 4,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith SGE 60

A.O. Smith SGE 60 User Manual - German - 120 pages

A.O. Smith SGE 60 User Manual - Dutch - 114 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info