29
3 Maintenance
3.1 Preparation for
maintenance
3.2 Water-side
maintenance
3.2.1
Warning
Maintenance may only be carried out by a competent person.
At each service, the water heater undergoes maintenance on water side. The maintenance
must be carried out in the following order.
1. Preperation for maintenance
2. Water-side maintenance
3. Finalizing maintenance
Note
Before ordering spaer parts, it is importent te write down the installation type, water heater
model and the full serial number of the water heater. These details can be found on the
rating plate. Only by ordering with this information can you be sure receive the correct spare
parts.
The preparation for maintenance consits out of testing and checking if all componets are still
working properly, complete the following steps:
1. Test the operation of the overflow valve of the protected cold supply setup. The water
should purt out.
2. Check the drainage pipes from the discharge points of all valves and remove any scale
deposits that may be present.
3. Drain the water heater.
Water-side maintenance consits ouf descaling and cleaning the tank and checking the
anodes.
Descaling and cleaning the tank
Scale and lime build-up prevent effective conduction of the heat to the water. Periodic
cleaning and descaling prevents build-up of these deposits. This increases the service life of
the water heater, and also improves the heating process.
Take the rate of scale formation into account when deciding on the service interval. Scale
formation depends on the local water composition, the water consumption and the water
temperature setting. A water temperature setting of maximum 60°C is recommended for the
prevention of excessive scale build-up.
To guarantee a good, watertight seal around the cleaning opening, replace the gasket,
washers, bolts and, if necessary, the lid with new parts before reassembly. Spare parts are
obtainable from the supplier/manufacturer.
To simplify descaling and cleaning of the tank, the water heater is equipped with a cleaning
opening.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith IT 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith IT 400 in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 0,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info