Code and description Cause Measure
F04 (lock out error)
Ignition error
Three unsuccessful
ignition attempts.
No gas. Make sure that the main gas supply valve
is open. If necessary, open the valve.
Make sure that the manual gas supply
valve, before the gas control valve, is
open. If necessary, open the valve.
Make sure that the gas supply pressure
to the gas control valve is correct, refer
to Gas supply pressure (see section
8.9.3).
Air in the gas pipes. Bleed the air out of the gas pipe.
Make sure that the gas supply pressure
to the gas control valve is correct, refer
to Gas supply pressure (see section
8.9.3).
Defect in the hot surface igniter circuit. Make sure that the hot surface igniter is
installed correctly.
Make sure that the wiring of the hot
surface igniter is not damaged.
Measure the resistance across the hot
surface igniter. This must be between the
36 and 72 Ohm (at room temperature).
Make sure that the hot surface igniter
lights up during ignition.
If necessary, replace the hot surface igniter.
Defect in the ionisation circuit. Make sure that the flame probe is
installed correctly.
Make sure that the wiring of the flame
probe is not damaged.
Measure the ionisation current. This
current must be a minimum of 3 μA
(parameter 109).
If necessary, replace the wiring and/or
flame probe.
Supply voltage too low. Make sure that the measured voltage is
230 V
AC
(-15%, +10%).
Bent flame probe is in contact with
metal surface.
Make sure that the flame probe is not
bend.
If necessary, replace flame probe.
Ceramic part, of the flame probe, is
broken or cracked.
Make sure that the ceramic part of the
flame probe is not broken or cracked in
the vicinity of the burner.
If necessary, replace flame probe.
0312266_INNOVO_UKUK_V3.0, 2017-02-10 77
77


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Innovo IR 32-380 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Innovo IR 32-380 in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Innovo IR 32-380

A.O. Smith Innovo IR 32-380 Usermanual and installation guide - German - 92 pages

A.O. Smith Innovo IR 32-380 Usermanual and installation guide - Dutch - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info