671741
65
Zoom out
Zoom in
Previous page
1/92
Next page
Make sure that there is no grit or other blockages in the drain pipe (3).
Make sure that the slope of the drain pipe is correct; 5 mm/m.
Install the condense trap onto the condensate drain.
Fig. Condensate drain
123
1. Condensate drain
2. Condense trap
3. Drain pipe
11.4 Gas-side maintenance
Do gas side maintenance when the water heater does not operate correctly, the air
pressure differential is not correct and/or the CO
2
value is not correct.
To do gas side maintenance:
Clean the burner (see section 11.4.1)
Clean the combustion chamber (see section 11.4.2)
11.4.1 Clean the burner
Remove the burner engine:
Close the gas control valve, refer to Installation diagram (see section 8.3).
Disconnect all plugs from the burner engine (1).
Disconnect the gas supply pipe (2).
Loosen the two bolts (3) to disconnect the burner engine (4) from the adapter.
Take the burner engine out of the water heater.
Fig. Remove the burner engine
2 1
4
3
1. Plugs on burner
engine
2. Gas supply pipe
3. Bolts
4. Burner engine
6.
7.
8.
1.
2.
3.
4.
5.
0312266_INNOVO_UKUK_V3.0, 2017-02-10 65
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Innovo IR 32-245 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Innovo IR 32-245 in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Innovo IR 32-245

A.O. Smith Innovo IR 32-245 Usermanual and installation guide - German - 92 pages

A.O. Smith Innovo IR 32-245 Usermanual and installation guide - Dutch - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info