671737
41
Zoom out
Zoom in
Previous page
1/92
Next page
8.5 Condensate drain
Caution
When the condensate drain is not connected to the waste water discharge by an open
connection, this can cause faults.
Caution
Do not change the condensate drain or cause any blockage in the condensate drain.
Install the condensate drain:
Install a drain pipe to the condense drain (13) for condensate drainage.
Make sure that the slope of the drain pipe is 5 mm/m.
Connect the drain pipe through an open connection to the waste water discharge.
8.6 Gas connection
Caution
Make sure that the gas supply pipe has the correct diameter and length to supply
sufficient capacity to the water heater.
Caution
Make sure that the gas supply pipe is clean. Contamination in the pipe can cause damage
to the gas control valve, during operation.
Caution
Install the manual gas valve on a spot accessible for the user.
Install the gas connection:
Install a manual gas valve (10) in the gas supply pipe.
Make sure that the gas pipe is clean before use. If necessary, remove the
contamination from the pipe.
Close the manual gas valve.
Install the gas supply pipe to the gas control valve.
Make sure that there are no gas leaks.
c
1.
2.
3.
c
1.
2.
3.
4.
5.
0312266_INNOVO_UKUK_V3.0, 2017-02-10 41
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Innovo IR 20-160 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Innovo IR 20-160 in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Innovo IR 20-160

A.O. Smith Innovo IR 20-160 Usermanual and installation guide - German - 92 pages

A.O. Smith Innovo IR 20-160 Usermanual and installation guide - Dutch - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info