Code and description Cause Measure
F03 (lock out error)
Air proving switch error
Switch is not closed when
fan is running during pre-
purge.
Hoses are damaged. Make sure that the hoses, between the
air proving switch and fan and the air
proving switch and gas control valve are
not damaged and reset the controller.
If necessary replace the hose(s)
When the hose(s) are replaced and
reconnected, reset the controller.
Wiring is damaged. Make sure that the wiring, between the
air proving switch and the control, is
connected and not damaged.
If necessary, replace the wires or
reconnect the wires.
When wires are replaced or reconnected,
reset the controller.
Leakage of air between venturi and
flexible air connector.
Make sure that the flexible air connector
is not damaged. If necessary, replace the
flexible air connector.
Make sure that the hose is properly
connected to the venturi. If necessary,
tighten the clamp.
Non return valve, between fan and
burner, is stuck.
Make sure that the non return valve can
move freely. If necessary replace the non
return valve.
Not enough pressure differential across
the air proving switch, due to:
venting system
malfunctioning condensation
discharge
dirty burner
blocked heat exchanger
Check, after each fix, if the error reappears.
If the error reappears continue in finding the
cause.
Measure the pressure differential across
the air proving switch, refer to Air
pressure differential (see section 8.9.2).
Venting system (see section 8.7):
Make sure if the venting system is
compliant.
Make sure that the venting system has
no blockages.
Make sure if the air inlet screen has no
blockages.
Condensation discharge:
Make sure the condensate drain has no
blockages.
Make sure that the condensate drain is
connected to the waste water discharge
by an open connection.
Burner:
Make sure that the the burner is clean
(see section 11.4.1).
Measure the pressure differential across
the air proving switch again. If the
pressure differential is insufficient, clean
the heat exchanger.
Make sure that the air proving switch is
closing, by using a multimeter.
76 Installation, Maintenance and Service part
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Innovo IR 12-200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Innovo IR 12-200 in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Innovo IR 12-200

A.O. Smith Innovo IR 12-200 Usermanual and installation guide - German - 92 pages

A.O. Smith Innovo IR 12-200 Usermanual and installation guide - Dutch - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info