Code and description Cause Measure
C05 (blocking error)
Control error
Content EEPROM not correct. Reset the controller.
If the error reappears, contact your supplier.
E01 (blocking error)
Temperature error
The temperature in the tank is above
90ºC.
Tap off water, so the temperature drops
in the water heater.
Reset the controller.
Make sure that there is no scale on the
temperature sensor. If necessary, replace
the sensor.
E03 (lock out error)
Temperature error
Temperature difference, between sensor
1 and sensor 2, is more then 10ºC, for
at least 60 seconds.
Make sure that the sensor wiring is
connected and not damaged. Reset the
controller.
If necessary replace the sensor and/or
wiring if the error reappears.
E05 (lock out error)
Control error
Control was in a blocking error for at
least 20 hours.
Press [RESET] to reset the water heater.
If the error reappears:
Find the cause of the blocking error
(parameter 272).
Remove the blockage and reset the
controller.
If the error reappears, replace the
controller.
F01 (blocking error)
Control error
Live and neutral are connected the
wrong way around.
Make sure that the live and neutral are
connected correctly and rectify if necessary.
Floating zero is present. Install an isolating transformer.
F02 (lock out error)
Fan error
Fan does not run on
correct speed
Damaged or disconnected wiring. Make sure that the wiring between the
fan and the controller is connected and
not damaged.
If necessary, replace the wiring. Reset
the controller when the wiring is
reconnected
Contaminated or blocked fan. Make sure that the motor and/or rotor of
the fan are not dirty or blocked.
If necessary remove the dirt and/or
blockage.
Reset the controller.
Make sure that the rotor of the fan can
rotate freely and reset the controller.
Due to a drop in supply voltage, the fan
will not run at the correct speed.
Make sure that the supply voltage is
correct and reset the controller.
The measured voltage must be 230 V
AC
(-15%, +10%)
Contact you maintenance and service
engineer when the supply voltage is not
correct.
Defective motor and/or rotor. Make sure that the motor and/or rotor
are not defective and reset the controller.
Replace the fan when the motor and/or
rotor are defective and reset the
controller.
74 Installation, Maintenance and Service part
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Innovo IR 12-200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Innovo IR 12-200 in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Innovo IR 12-200

A.O. Smith Innovo IR 12-200 Usermanual and installation guide - German - 92 pages

A.O. Smith Innovo IR 12-200 Usermanual and installation guide - Dutch - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info