Parameter Description Unit/Value Adjustable Range Default
116
Status burner Initialization
Reset
Stand-by
Pre-purge (1)
Pre-Purge (2)
Pre-Ignition
Ignition
Flame check
Burn
Post-Burn
Post-Purge (1)
Post-Purge (2)
Blocking
Lockout
Warning
Burner Boot
No
0 - Initialization
1 - Reset
2 - Stand-by
3 - Pre-purge
(part 1)
4 - Pre-Purge
(part 2)
5 - Pre Ignition
6 - Ignition
7 - Flame check
8 - Burn
9 - Post Burn
10 - Post Purge (part 1)
11 - Post Purge (part 2)
12 - Blocking
13 - Lockout
14 - Warning
15 - Burner Boot
-
117
Actual error number # No
C02S13
--- - no error
-
120
Time left till service reminder
appears on display
Months
Days
No
≥ 1 Month = 01 - 36
< 1 Month = 01d - 31d
12
201
Test cycle
dIS
FAn
Lo
Ign
Hi
rEg
Yes
dIS - leave test cycle
FAn - pre-purge on ignition
speed
Lo - burn on partial load
Ign - burn on ignition speed
Hi - burn on full load
rEg - t.b.d.
dIS
202
Turn the power anode warning
on or off.
Off
ON
Yes
Off - power anodes deactivated
ON - power anodes activated
ON
203
Minimum fan speed ×10 rpm No
0990
-
204
Ignition fan speed ×10 rpm No
0990
-
205
Maximum fan speed ×10 rpm No
0990
-
207
Maximum setpoint ºC No
4085 70
208
Minimum load % Yes
050
0 and 1 = minimum load
50 = 50% between minimum
load and maximum load
0
211
Service reminder
Off
ON
rst
Yes
Off - service reminder off
ON - service reminder on
rst - reset service reminder
ON
212
Setting service interval Months Yes
036 12
270
Last lock-out error # No
C02S14
--- - no error
-
271
Interval between last lock-out
and read-out.
Minutes
Hours
Days
Weeks
No
00n...59n = 0 till 59 minutes
01h...23h = 1 till 23 hours
01d...06d = 1 till 6 days
01...63 = 1 till 63 weeks
-
272
Last blocking error # No
C02S14
--- - no error
-
60 Installation, Maintenance and Service part
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Innovo IR 12-200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Innovo IR 12-200 in the language / languages: English as an attachment in your email.

The manual is 7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Innovo IR 12-200

A.O. Smith Innovo IR 12-200 Usermanual and installation guide - German - 92 pages

A.O. Smith Innovo IR 12-200 Usermanual and installation guide - Dutch - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info