Fault Possible cause Corrective action
3.2 Fault finding
Blocked pilot burner
Blocked chimney
Safety thermostat
Thermocouple defective
Thermocouple makes no
contact
Gas supply closed
Down draught
supervision not
connected.
Temperature is set too
low
Control knob in position
() (pilot burns )
Control knob in position
()
Flue safety device closed
the gas supply
Gas supply closed
Gas smell
Pilot
extinguishes
Insufficient
hot water, or
none at all
If you smell gas you should immediately
close the main gas tap you should not
light any fire or switch on light,
electrical switches or bells. Open
windows and immediately contact your
installer or the local gas company.
Clean the pilot burner
Find the cause and remove it.
Set the temperature regulator at a lower
temperature.
Replace the thermocouple
Restore the connection
Open the gas tap
Connect by sliding the two connectors
of the down draught supervision on to
the thermocouple.
Set the temperature regulator at a higher
temperature
Turn the temperature regulator
completely clockwise; turn control button
to “on” (
); turn the temperature
regulator to the desired position,
preferably position 4. The appliance now
operates fully automatically.
Put the appliance into operation.
Press the reset button - if present - on
the safety thermostat and put the
appliance into operation. If this occurs
more often then you should inform your
installer.
Open the gas tap and put the appliance
into operation.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith EQ 155 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith EQ 155 in the language / languages: English as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith EQ 155

A.O. Smith EQ 155 User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info