671777
41
Zoom out
Zoom in
Previous page
1/48
Next page
Installation and Service Manual Epsilon-Series
41
Annex A Technical specications
Technical specifications Natural Gas
Boiler type EB 40 EB 50
Type heat exchanger HEX2 HEX3
Input Hs CH kW 38 51
Q
n
Input Hi CH
kW 34,2 45,9
Efficiency class according BED  
Efficiency according EN677 (36/30°C part load, Hi
)
% 109,1 109,3
Efficiency according EN677 (80/60°C full load, Hi
)
% 97,4 97,3
Modulation range CH (capacity 80/60°C) kW 6.0 - 33.3 8.8 - 44.7
Modulation range CH (capacity 50/30°C) kW 6.8 - 36.3 9.8 - 48.7
Nox class EN483
55
O
2
CO
2
%
%
CO ppm
100 100
Flue gas non-return valve present
no no
Flue gas temp. CH (80/60°C on full load) °C 69 70
Flue gas temp. CH (50/30°C on low load) °C 31 31
Gas consumption G20 CH at 1013 mbar/15°C
m
3
/h
3,62 4,86
Gas category
Boiler flue category
Electr. power consumption max. W 133 136
Electr. power consumption stand by W 10 10
Current V/Hz 230/50 230/50
Fuse rating
A5 5
Degree of protection acc. EN 60529 IPX0D IPX0D
Weight (empty) kg 53 64
Width mm 500 660
Height mm 680 680
Depth mm 385 385
Water content CH l 5 7
After run time pump CH min 5 5
P
MS
Water pressure min./max.
bar 1/3 1/3
Flow temperature max. °C 85 85
Pump type UPM2 20-70 20-70
Available pump height CH
kPa
20
Low velocity header required
CE product identification number(PIN)
Technical specifications Propane Gas
Boiler type EB 40 EB 50
Type heat exchanger HEX2 HEX3
O
2
%
CO
2
%
Restriction diameter mm 5,2 5,7
Display indication 38.P 51.P
Pre pressure mbar
Load (H
i
)
kW 34,2 45,9
Gas consumption kg/h 2,74 3,68
Gas consumption
m
3
/h
1,40 1,88
Modulation range(80/60°C) kW 15,6 - 33,3 30,3 - 44,7
Modulation range(50/30°C) kW 17,5 - 36,3 33,0 - 48,7
ErP specifications according to European Directive 2010/30/EU
Boiler type EB 40 EB 50
Seasonal space heating energy efficiency clas
s
AA
Rated heat output of preferential heater (P
n
)
kW
33 45
Annual energy consumption (Q
HE
)
GJ
11 15
Seasonal space heating energy efficiency of the preferential heater (η
s
)
%
93 93
Sound power level, indoors (L
WA
)
dB
50 54
5,1% (-1,2%, +0,7%)
10,3% (-0.4%, +0.8%)
Epsilon
Epsilon
see type plate propane
0063BQ3021
Epsilon
II2H3P
B23 B33 C13 C33 C43 C53 C63 C83 C93
4,7 (-1,2%, +0,8%)
9 (-0,4%, +0,6%)
NOTE: The Epsilon boilers can be run on propane/lpg. The lpg-gas has to have
a propane purity of at least 90%. When the butane-level is greater then 10% the
warranty conditions on the heat exchangers are not valid.
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Epsilon EB 40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Epsilon EB 40 in the language / languages: English as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Epsilon EB 40

A.O. Smith Epsilon EB 40 User Manual - English - 16 pages

A.O. Smith Epsilon EB 40 User Manual - Dutch - 16 pages

A.O. Smith Epsilon EB 40 Installation Guide - Dutch - 48 pages

A.O. Smith Epsilon EB 40 Installation Guide - French - 44 pages

A.O. Smith Epsilon EB 40 User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info