8 Boiler controls
The boiler is provided with a fully automatic microprocessor control, called CMS Control
Management System. This control simplies operation by undertaking all major control
functions. Initially when power to the unit is switched on it will remain on standby. There is
no indication Led on, untill one of the program keys is pressed. The control panel display
will show the relevant state. When the installation is empty the display will show FILL.
The various parameters can be called up in two ways:
The Good-state or standard read out
The rst way shows a simple display read out.
The boiler in operation will always show 'Good'. When a message is necessary this will
be shown instead of Good.
Technical read out
The second way is a technical read out. In normal situations the following will be shown:
on the left the status in which the boiler is active;
on the right the ow temperature;
the water pressure in the installation.
When a message (error or blocking code) is necessary this will be shown instead of the
technical read out..
To switch over from the Good-state to the Technical read out (and vice versa):
- Press 5 sec. on the STEP-key.
When the system has been lled the automatic venting program starts, when a program has
been selected, by pressing the key for Central Heating, DHW or pump program (
,
of ). The program takes 17 minutes and stops automatically. After this the unit
will function normally. (See also chapter 9 'Filling and venting the boiler and installation').
On a call for heating or hot water the control system will select the required water control
temperature. This water temperature is called the T-set value. On a call for central heating
the boiler ignites rst at low input. The input is then changed slowly to match the load
required. The boiler operates in this way to avoid excessive water noises and temperature
overshoot.
If during a call for heating the burner switches o, because the desired heating tem-
perature is exceeded, then there will be an anti-commuting time in operation for ve
minutes. This means that the burner switches on again after 5 minutes if there is still a
call for heating.
On a call for hot water supply the T-set value of central heating return water temperature is
monitored. Depending on the amount of sanitary water which is withdrawn from the DHW
cylinder, the central heating return water temperature, from which the input is adjusted,
will vary.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Epsilon EB 40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Epsilon EB 40 in the language / languages: English as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Epsilon EB 40

A.O. Smith Epsilon EB 40 User Manual - English - 16 pages

A.O. Smith Epsilon EB 40 User Manual - Dutch - 16 pages

A.O. Smith Epsilon EB 40 Installation Guide - Dutch - 48 pages

A.O. Smith Epsilon EB 40 Installation Guide - French - 44 pages

A.O. Smith Epsilon EB 40 User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info