5 Mounting the boiler
Install the boiler in a well-ventilated boiler room in accordance to the actual
regulations.
The room where the boiler will be placed must always be frost free.
It is NOT necessary to have a purpose provided air vent in the room or internal space in
which the boiler is installed. Neither is it necessary to ventilate a cupboard or compartment
in which the boiler is installed, due to the extremely low surface temperature of the
boiler casing during operation. Therefore the requirements of BS 6798, Clause 12, and
BS5440:2 may be disregarded.
The boiler can be mounted practically to any wall with the suspension bracket and the
enclosed xing equipment. The wall must be at and of sucient strength in order to be
able to carry the boiler weight with its water content.
Above the boiler there must be at least 250 mm working space in order to be able to t a
coaxial ue system or a twin supply. On the left side of the boiler at least 50 mm and on
the right side 10 mm must be reserved to allow tting or removing of casing. The location
of the boiler can be determined by using the template located inside the boiler packaging.
Lift the boiler only by the boilers rear wall.
Lifting and carrying precautions:
- Lift only a manageable weight, or ask for help.
- When lifting the boiler, bend the knees, and keep the back straight and feet
apart.
- Do not lift and twist at the same time.
- Lift and carry the boiler close to the body.
- Wear protective clothing and gloves to protect from any sharp edges.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith Epsilon EB 40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith Epsilon EB 40 in the language / languages: English as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith Epsilon EB 40

A.O. Smith Epsilon EB 40 User Manual - English - 16 pages

A.O. Smith Epsilon EB 40 User Manual - Dutch - 16 pages

A.O. Smith Epsilon EB 40 Installation Guide - Dutch - 48 pages

A.O. Smith Epsilon EB 40 Installation Guide - French - 44 pages

A.O. Smith Epsilon EB 40 User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info