503230
22
Zoom out
Zoom in
Previous page
1/70
Next page
Installation
22 Installationsanleitung BFM
3
is
3.4.3 Gasdaten
Gasdaten
Beschreibung II
2ELL3B/P
Einheit BFM
30
BFM
50
BFM
80
BFM
100
BFM
120
Erdgas
Allgemein
Durchmesser Wachflamme
Einspritzdüse
mm 0,56/0,41 0,56/0,41 0,56/0,41 0,56/0,41 0,56/0,41
(1) = Flache Platte
(2) = Brenner-Druckregler
1 oder 222222
G20 - 20 mbar
Durchmesser Einspritzdüse mm 2,60 2,50 2,70 3,20 3,30
Nennbelastung (Unterwert) kW 29,0 47,0 75,0 102,0- 115,0
Nennleistung kW 26,4 42,3 67,5 90,8 102,4
Vordruck mbar 20 20 20 20 20
Brennerdruck
(†)
mbar 12,5 12,9 12,9 12,5 14,0
Gasverbrauch
(*)
m
3
/h 3,1 5,0 7,9 10,8 12,2
G25 - 20 mbar
Durchmesser Einspritzdüse mm 3,00 2,70 3,05 3,50 3,70
Nennbelastung (Unterwert) kW 32,0 45,0 77,0 102,0 115,0
Nennleistung kW 29,1 40,5 69,3 90,8 102,4
Vordruck mbar 20 20 20 20 20
Brennerdruck
(†)
mbar 12,5 12,5 12,5 12,5 14,0
Gasverbrauch
(*)
m
3
/h 3,9 5,5 9,5 12,6 14,2
Flüssiggas 3B/P: G30 - 50 mbar (Butan)
Durchmesser Einspritzdüse mm 1,25 1,25 1,30 1,70 2,10
Durchmesser Wachflamme
Einspritzdüse
mm 0,25 0,25 0,25 0,25 0,25
(1) = Flache Platte
(2) = Brenner-Druckregler
1 oder 211112
Nennbelastung (Unterwert) kW 29 45 75 102 115
Nennleistung kW 26,4 40,5 67,5 90,8 102,4
Vordruck mbar 50 50 50 50 50
Brennerdruck
(†)
mbar----25,0
Gasverbrauch
(*)
kg/h 2,3 3,5 5,9 8,0 9,1
(*) basierend auf 1013,25 mbar und 15 °C.
(†) Bei Verwendung einer flachen Dichtungsplatte anstelle eines Brenner-Druckreglers wird davon ausgegangen,
dass Brennerdruck und Vordruck gleich sind. Der Brennerdruck ist jedoch in der Praxis niedriger.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith BFM100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith BFM100 in the language / languages: German as an attachment in your email.

The manual is 2,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith BFM100

A.O. Smith BFM100 Usermanual and installation guide - English - 74 pages

A.O. Smith BFM100 User Manual - Dutch - 70 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info