Instruction manual BFC 76
F01 (blocking error)
Defect in power supply
circuit
Live and neutral
connected wrong way
around.
Be sure to connect the live and neutral correctly (3.10 "
Electrical
connection"); the water heater is phase-sensitive
See the electrical diagram (17 "
Appendices").
Condensation on the
flame probe
1. Disconnect the lead at the flame probe
2. Ignite the water heater three times, with an interrupted
ionisation circuit
3. Reconnect the ionisation lead to the flame probe
4. Ignite the water heater again
5. The repeated ignition attempts will have caused the
condensation to evaporate
If errors persist, contact your installation engineer
Floating neutral Install an isolating transformer (3.10.4 "
Isolating transformer") Contact your installation engineer to have an isolating transformer
installed
F02 (lock out error)
Fan fails to run at
correct speed.
Defective motor and/or
rotor.
1. Check the motor and rotor
2. Replace the fan if the motor or rotor is defective.
3. Reset controller
See the electrical diagram (17 "Appendices").
To have the wiring replaced and a new fan fitted, you must contact
your installation engineer
Damaged wiring 1. Check the wiring between the fan and the controller.
2. If any wires are damaged, the wiring harness must be replaced.
3. Reset controller
Contaminated or
blocked fan
1. Check if the fan is dirty and repair it if necessary.
2. Check that the rotor can rotate freely
3. Reset controller
If the error cannot be resolved or is persistent, contact your
installation engineer
Because of a drop in
the supply voltage, the
fan will not run at the
correct speed.
1. Check the supply voltage, this must be 230 V
AC(-15%, +10%)
2. Reset controller
Code + description Cause Measure Remark
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith BFC80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith BFC80 in the language / languages: English as an attachment in your email.

The manual is 3,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith BFC80

A.O. Smith BFC80 Usermanual and installation guide - German - 100 pages

A.O. Smith BFC80 User Manual - Dutch - 116 pages

A.O. Smith BFC80 Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info