503219
24
Zoom out
Zoom in
Previous page
1/100
Next page
24 Instruction manual BFC
3.4.3 Gas data
II
2H3P
description Unit BFC 28 BFC 30 BFC 50 BFC 60 BFC 80 BFC 100 BFC 120
Gas category 2H: G20 - 20 mbar
Diameter of the venturi restrictor mm - - - - 8.60 8.60 8.60
Nominal load (upper value) kW 32.2 33.3 52.2 63.3 86.6 105.5 128.8
Nominal output kW 31.0 32.7 50.3 60.4 84.2 100.7 121.8
Supply pressure mbar 20 20 20 20 20 20 20
CO
2
(full load) Vol% 9.0 + 1.0 9.0 + 1.0 9.0 + 1.0 9.0 + 1.0 8.9 + 1.0 8.9 + 1.0 8.9 + 1.0
Gas consumption* m
3
/h 3.1 3.2 5.0 6.0 8.3 10.1 12.3
Emissions of Nitrogen Oxides (NO
2
) mg/kWh24323637343637
Gas category 3P: G31 - 37 / 50 mbar
Diameter of the venturi restrictor mm 6.00 6.00 6.00 6.00 6.60 6.60 6.60
Nominal load (upper value) kW 31.5 32.6 51.1 62.0 84.8 103.3 126.1
Nominal output kW 31.0 32.7 50.3 60.4 84.2 100.7 121.8
Supply pressure mbar 37 / 50 37 / 50 37 / 50 37 / 50 37 / 50 37 / 50 37 / 50
Gas control valve pressure mbar 12.0 +
2.0 12.0 + 2.0 12.0 + 2.0 12.0 + 2.0---
CO
2
(full load) Vol% 10.0 + 1.0 10.0 + 1.0 10.0 + 1.0 10.0 + 1.0 9.6 + 1.0 9.6 + 1.0 9.6 + 1.0
Gas consumption* kh/h 2.3 2.3 3.7 4.4 6.1 7.4 9.0
(*) Based on 1013.25 mbar and 15°C.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith BFC80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith BFC80 in the language / languages: English as an attachment in your email.

The manual is 3,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith BFC80

A.O. Smith BFC80 Usermanual and installation guide - German - 100 pages

A.O. Smith BFC80 User Manual - Dutch - 116 pages

A.O. Smith BFC80 Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info