Instruction manual BFC 73
Water leakage Leakage from a water
connection (threaded)
Tighten the threaded connection If the leak persists, consult your installation engineer
Condensate leakage Check that the condensation water discharge is working properly.
Rectify if necessary
Leakage from another
nearby water water
heater or pipe segment
Trace the leak
Leakage from the water
heater tank
Consult the supplier and/or manufacturer
Explosive ignition Incorrect supply
pressure and/or CO
2
Set (3.11 "Check the supply pressure, gas control valve pressure,
CO
2
value and switching pressure") the correct supply pressure
and/or CO
2
.
If ignition is not improved, consult your installation engineer.
Contaminated burner Clean the burner (15.4.2 "
Cleaning the burner")
Insufficient or no hot
water
The water heater is off Start the water heater (9 "Starting the water heater")
No supply voltage
present
1. Check whether the isolator is ON.
2. Check that there is power to the isolator.
3. Check whether the ON/OFF switch of the controller is ON
(position I).
4. Check whether there is power to the electrical connector block.
5. The measured voltage must be 230 V
AC (-15%, +10%)
See the electrical diagram (17 "
Appendices").
If the error persists, consult your installation engineer.
Hot water supply is
used up
Reduce hot water consumption and give the water heater time to
heat up.
If there continues to be insufficient or no hot water, consult your
installation engineer.
The controller is in the
OFF position.
Switch the controller to the ON position (11.3 "
Switching to "ON
mode"").
Temperature (T
set
) is
set too low.
Set temperature (T
set
) to a higher setting (11.4 "Setting the water
temperature").
Indication Cause Measure Remark
73


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith BFC60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith BFC60 in the language / languages: English as an attachment in your email.

The manual is 3,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith BFC60

A.O. Smith BFC60 Usermanual and installation guide - German - 100 pages

A.O. Smith BFC60 User Manual - Dutch - 116 pages

A.O. Smith BFC60 Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info