503220
31
Zoom out
Zoom in
Previous page
1/100
Next page
Instruction manual BFC 31
is
Water heater with concentric flue gas discharge material
According to the table, the maximum length allowed is 40 metres, and there may
be up to seven 90 degree bends. Both requirements are fulfilled.
Specifications
Caution
For type C13 and C33 installations,A.O.Smith prescribes the use of a roof
or wall flue terminal, exclusively of a type approved for the water heater. Use of
an incorrect roof or wall-mounted flue terminal can cause the installation to
malfunction.
Concentric wall flue terminal specifications C13
IMD-0791 R0
Subject Description
Wall flue terminal set:
1x Wall flue terminal (incl. wall
flange & clamping ring)
1x Pipe 500 mm
•1x 90
o
bend
Art. No. BFC 28, 30, 50, 60 0302 504
1
BFC 80, 100, 120 0311 465
1
Manufacturer Muelink & Grol
Type M2000 MDV SEC
Pipe material Construction Concentric
Flue gas discharge Thick-walled aluminium with lipped sealing ring.
Air supply Thin-walled galvanised sheet steel.
Pipe diameters Flue gas discharge BFC 28, 30, 50, 60 Ø 100 mm
BFC 80, 100, 120 Ø 130mm
Air supply BFC 28, 30, 50, 60 Ø 150 mm
BFC 80, 100, 120 Ø 200 mm
(1)
No other wall flue terminal is permitted. Use this item number to order the wall conduit set from supplier,
manufacturer or wholesaler.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith BFC100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith BFC100 in the language / languages: English as an attachment in your email.

The manual is 3,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith BFC100

A.O. Smith BFC100 Usermanual and installation guide - German - 100 pages

A.O. Smith BFC100 User Manual - Dutch - 116 pages

A.O. Smith BFC100 Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info