503238
29
Zoom out
Zoom in
Previous page
1/96
Next page
Instruction manual ADMR 29
is
3.9.4 Fitting the flue gas sensor
Attached to the control column is a plastic bag containing the flue gas sensor
and related mounting components.
The sensor lead is already connected inside the control column, but not
Flue gas safety
Fit the flue gas sensor as follows:
1. Take the bracket (1) (with flue gas sensor (2) already fitted) from the
packaging.
2. Place the bracket in the draught diverter and screw the bracket firmly in
place.
3. Bend the cable clips (3) around the flue gas sensor lead.
4. Click the plug (4) of the sensor cable (5) into the flue gas sensor.
5. Screw the cable clips (3) tightly into the draught diverter and the
3.10 Electrical
connection
Warning
The installation should be carried out by an authorised installation engineer,
in compliance with general and local regulations (1.3 "Regulations").
3.10.1 Introduction
Topics covered in this paragraph:
•Preparation
;
Connecting the mains power
;
Connecting flue damper
.
Optionally, it is possible to connect an isolating transformer, a continuous pump,
a program-controlled pump, an extra ON mode switch and an extra alarm signal
to the appliance. For these options, see:
Connecting an isolating transformer
;
Connecting a continuous pump;
Connecting top to bottom circulation pump
;
Connecting an extra ON mode switch ("Tank ON")
;
Connecting an extra error signal ("Alarm OUT").
Note
The optional components are not included in the rating for electrical power
consumption stated in the table (3.4.2 "General and electrical specifications").
Legend
1 bracket
2 flue gas sensor
3 fastening bracket
4plug
5 sensor lead
2
1
3
4
5
IMD-0120 R1
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith ADMR135 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith ADMR135 in the language / languages: English as an attachment in your email.

The manual is 2,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith ADMR135

A.O. Smith ADMR135 User Manual - Dutch - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info