Instruction manual ADMR 21
3.4.3 Gas data
Description II
2H3+
Unit ADMR 40 ADMR 50 ADMR 60 ADMR 80 ADMR 90 ADMR 115 ADMR 135
Gas category 2H: General
Orifice diameter mm 3.20 3.20 3.10 2.95 3.20 3.20 3.90
(1) = Blank plate
(2) = Burner pressure regulator
(3) = High/low regulator
1, 2 or 3 2 2 2 2 2 2 2
Gas category G20 - 20 mbar
Nominal load (gross calorific value) kW 42.2 56.5 66.4 82.5 98.3 126.6 143.4
Nominal output kW 32.3 42.8 50.2 62.4 74.3 95.8 109.8
Supply pressure mbar 20 20 20 20 20 20 20
Burner pressure mbar 8.5 8.5 8.5 8.5 8.5 8.5 11.3
Gas consumption
(*)
m
3
/h 4.0 5.4 6.3 7.9 9.4 12.1 13.7
Emissions of Nitrogen Oxides (NO
2
) mg/kWh 240 235 235 229 283 311 276
Gas category 3+: General
Orifice diameter mm 1.70 1.70 1.70 1.50 1.70 1.70 2.25
(1) = Blank plate
(2) = Burner pressure regulator
(3) = High-low control
1, 2 or 3 1 1 1 1 1 1 3
Gas category G30 - 30 mbar
Nominal load (gross calorific value) kW 41.6 55.3 68.2 80.7 96.1 123.5 138.4
Nominal output kW 32.6 42.8 52.8 62.6 74.5 95.8 108.5
Supply pressure mbar 30 30 30 30 30 30 30
Burner pressure
(†)
mbar-------
Gas consumption
(*)
kg/h 3.0 4.0 5.0 5.9 7.0 9.0 10.1
Gas category G31 - 37 mbar
Nominal load (gross calorific value) kW 38.4 51.1 63.3 77.7 89.6 113.0 130.1
Nominal output kW 30.0 39.5 48.9 60.1 69.2 87.4 101.7
Supply pressure mbar 37 37 37 37 37 37 37
Burner pressure
(†)
mbar-------
Gas consumption
(*)
kg/h 2.7 3.7 4.5 5.6 6.4 8.1 9.3
(*) Based on 1013.25 mbar and 15 °C.
(†) If using a blank plate instead of a burner pressure regulator, it is assumed that the burner pressure is equal to the supply pressure. In practice, however, the burner pressure will be lower.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith ADMR135 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith ADMR135 in the language / languages: English as an attachment in your email.

The manual is 2,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith ADMR135

A.O. Smith ADMR135 User Manual - Dutch - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info