Performing maintenance
54 Instruction manual ADM
12
s
12.3 Water-side
maintenance
12.3.1 Introduction
The following steps must be carried out on the water side:
1. Checking the anodes
.
2. Descaling and cleaning the tank
.
12.3.2 Checking the anodes
Timely replacement of the anodes extends the service life of the appliance. The
appliance's anodes must be replaced as soon as they are 60% or more
consumed (take this into consideration when determining the maintenance
frequency).
Warning
The draught diverter and the cover may be hot.
1. Remove the protective cover from the control column by unscrewing the 4
screws in the cover.
2. Detach the wiring for the flue gas thermostat from the connector block and
remove the cable from the strain relief.
3. Remove the cable clamps holding the flue gas thermostat cable.
4. Disconnect the draught diverter from the flue gas discharge.
5. Undo the screws on the draught diverter.
6. Remove the draught diverter from the appliance.
7. Undo the screws of the lid in the top side of the appliance.
8. Remove the lid from the appliance.
9. Remove the sealing ring from the appliance.
10. Loosen the anodes using suitable tools.
11. Check the anodes, and replace them if necessary.
12. Now also check the flue baffles (12.4.4 "
Checking the flue baffles"). If
necessary, replace them.
13. Place a new sealing ring on the rim of the tank and re-fit the lid.
14. Fit the draught diverter (3.9.2 "
Fitting the draught diverter").
15. Feed the cable of the flue gas thermostat through the strain relief and attach
the wiring to the connector block (14.2 "
Electrical diagram").
16. Refit the cable clamps to the appliance and draught diverter.
17. Re-fit the protective cover.
12.3.3 Descaling and cleaning the tank
Scale and lime buildup prevent effective conduction of the heat to the water.
Periodic cleaning and descaling prevents buildup of these deposits. This
increases the service life of the appliance, and also improves the heating
process.
Take the rate of scale formation into account when deciding on maintenance
frequency. Scale formation depends on the local water composition, the water
consumption and the water temperature setting. A water temperature setting of
maximum 60 °C is recommended for prevention of excessive scale buildup.
To ensure the perfectly watertight sealing of a cleaning opening, the gasket (6),
O-ring (7), sealing rings (4), bolts (3) and possibly the lid (5) should be replaced
with new components after opening (see the figure). A special set is obtainable
from the supplier/manufacturer.
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith ADM 115 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith ADM 115 in the language / languages: English as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith ADM 115

A.O. Smith ADM 115 Usermanual and installation guide - Dutch - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info