is
3.9.3 Flue gas thermostat assembly
At the top of the control column there is a plastic bag containing the flue gas
sensor plus the associated fastenings. The cable from the sensor has already
been connected to the control column. The sensor must be fitted in the cut-away
of the draught diverter.
Warning
If the sensor is not (or is incorrectly) fitted/connected, the flue gas discharge
will not be protected. An incorrectly fitted chimney can cause flue gases to
backflow into the boiler room.
Flue gas thermostat
Fit the sensor as follows:
1. Take the bracket (1) and sensor (2) from the packaging.
2. Place the cable (3) for it along the appliance.
Warning
NEVER place this cable across the top of the appliance. This could cause
it to burn.
3. Fix the cable alongside the appliance using the fittings supplied (4).
4. Attach the bracket with the sensor into the cut-away on the draught diverter.
5. Attach the sensor using the fixtures provided onto the bottom of the draught
diverter. The sensor should protrude half way (6) out of the draught diverter.
Legend
1. bracket
2. sensor
3. cable
4. attachment brackets
5. cut-away
6. sensor fastenings
2
1
3
4
IMD-0137 R2
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith ADM 115 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith ADM 115 in the language / languages: English as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith ADM 115

A.O. Smith ADM 115 Usermanual and installation guide - Dutch - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info