The friction surfaces of the door hinges and closing device must be treated with graphite
grease from time to time. Before each heating season the whole stove must be inspected and
cleaned. Give special care to checking the sealing for its integrity, and replace it, if necessary.
ASH REMOVAL
Ash should be removed prior to each time you light the stove. To remove the ash, just empty
the ash container located below the fire grate. Regular hearth-ash removal prevents the ash
from spilling out. Do not allow ash to spill over the barrier. Remove the ash from the stove
when it is cold.
SPARE PARTS
If after many years you find exchanging some parts necessary, contact the supplier or any
representa- tive of our company. To order a spare part, submit the information listed in the
rating plate located on the back of the guarantee certificate, which must be kept even when the
guarantee has terminated.
If you have this information, and our factory documentation, the supplier will be able to deliver
all spare parts in a short time.
POSSIBLE IRREGULARITIES DURING THE OPERATION OF THE APPLIANCE
During the operation of the appliance there can occur some irregularities which indicate that it
is working improperly. This can be caused either by the incorrect installation of the appliance -
without adhering to the valid construction provisions or the instructions in this Manual, or for
reasons beyond one’s control, e.g. the natural environment.
The next section shows the most-frequent reasons for the incorrect operation of the appliance,
and how to remedy such occurrences.
a)Back-puffing when the door is open:
- the door is opened too abruptly (open the door slowly); slide the primary air damper towards
the closed position
- if a flue damper is fitted as a chimney-draught control, open the flue damper each time you
open the door;
- Insufficient air supply to the room in which the appliance is installed (provide adequate
ventilation in the room or supply air to the combustion chamber in accordance with the
instructions in the Manual, if possible for the right model);
- weather conditions: low pressure, fog and precipitation, sudden temperature changes;
- insufficient chimney draught (have the chimney flue inspected by a chimney sweep).
b) Too-low heating, or the fire goes out:
- too little fuel in the hearth (load the hearth according to the Manual);
- too-high humidity of the wood used for burning (use wood with a humidity of up to 20%); a
large portion of the energy obtained is lost in the process of water evaporation;
- insufficient chimney draught (have the chimney flue inspected by a chimney sweep).
c) Insufficient heating in spite of proper burning in the combustion chamber:
- low-calorific softwood (use wood which meets the guidelines in the Manual);
- too-high humidity of the wood used for burning (use wood with a humidity of up to 20%);
- too fragmented wood, too-thick wood billets:
d) Excessive glass-dirt accumulation:
- low-intensity burning (when burning with a very-low flame, use dry wood fuel only);
- the use of high-resin softwood as fuel (use dry hardwood fuel in compliance with the firebox-
-operation manual).
e) The operation can be affected by weather conditions (air humidity, fog, wind, air pressure),
and sometimes by surrounding tall buildings.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.Caminetti SCANDINAVIAN series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.Caminetti SCANDINAVIAN series in the language / languages: English as an attachment in your email.

The manual is 2.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.Caminetti SCANDINAVIAN series

A.Caminetti SCANDINAVIAN series User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info