- Read the heater’s Operation Manual and adhere to its instructions at all times; -The stove must be
installed and started by an installer complying with the safety rules; - Do not leave any heat-sensitive
items near the stove glass, do not put out the fire in the hearth with water, do not operate the stove
when its glass is fractured, do not allow any flammable items near the stove; - Any items made of
flammable materials must be put at a distance of at least 1.5 m from the hearth - Do not let your
children near the stove - Have all repairs done by an installer and use spare parts from the manufacturer
only - Any structural, installation or operational changes are not allowed without the written consent of
the manufacturer.
Air can be supplied to the combustion chamber from within the room or from outside. The stove is fit-
ted with an in-built outside air-intake opening - connector dia. 100 mm. The adjustment of the primary
air under the fire grate is effected by means of a single control device below the firebox door. The stove
is fitted with a triple combustion-chamber air-feed system, with primary and secondary airs. The air is
redirected into the combustion chamber inside the space (air chamber) below the fire grate on which
combustion takes place. The primary air is supplied to the underneath of the fire grate which is on the
floor of the combustion chamber. The secondary chamber is supplied through a special con- duit
(located on the back wall of the stove), along the system of openings into the combustion cham- ber.
The secondary combustion is the burn-out of the particles contained in the smoke. The stove is also
fitted with an over-door air-curtain system. The air is directed through a turning vane and“sweeps” the
glass separating the flames and smoke from it, which largely reduces any soot depositing on it. In this
way oxygen is supplied to the upper section of the combustion chamber in which the gases gene- rated
during the wood burning are burnt out, which reduces the air emissions of toxic CO. Some models
feature an additional air damper installed in the air supply, independently of the in-built control device.
The stove consumes air for its operation, so the proper ventilation of the room in which it is installed is
required. The supply grilles of the ventilation system in the room should be protected against au-
tomatic closing.
The stove should be positioned on a non-flammable floor which is at least 2.030 mm thick, and the
flammable floor in front of the heater door should be separated with at least a 30-cm area of non-flam-
mable material (e.g. ceramic or vitrified tiles, stone, glass or steel base).
A stove with the connecting components of the flue-discharge system must be at a distance of at least
60 cm from any uncovered flammable structural components of the building, and at least 20 cm from
the covered ones. The distance from the side and back walls of the stove to the flammable materials
must be a min. of 20 cm, and the distance from the stove door/glass to the flammable materials must be
min. 80 cm. Remember that during all stove operation and maintenance work the temperature of the
stove’s steel parts might be high, so wear heat-resistant gloves for the stove’s operation. Follow the
rules which ensure the basic safety conditions for all operation and use of the stove.
THE VENTILATION OF THE ROOM WITH THE STOVE INSTALLED
POSITIONING THE STOVE AT A SAFE DISTANCE
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.Caminetti SCANDINAVIAN series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.Caminetti SCANDINAVIAN series in the language / languages: English as an attachment in your email.

The manual is 2.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.Caminetti SCANDINAVIAN series

A.Caminetti SCANDINAVIAN series User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info