813871
22
Zoom out
Zoom in
Previous page
1/30
Next page
-
-
-
The parts used for connections must be designed according to standard DIN EN 13384.
- A steel tube (chimney flue) designed for connecting the fireplace insert to the chimney and
containing a CE label can be used (the minimum thickness of the wall is 2 mm, for stainless
steel, 1 mm).
- If the draught in the chimney during the operation of fireplace insert is too high (more than
20Pa), it is recommended to install a chimney flap. In this case, make sure that:
- the flap is not automatically closed
- the flap has easy and clear control and the closed and open positions are marked
-
AIR SUPPLY FOR BURNING
- The fireplace insert must only be operated in rooms with a sufficient supply of air for burning.
Equipment for extracting air (e.g. ventilation equipment, steam exhausting unit), which is
operated with the fireplace insert in one room, may interfere with the air supply into the fireplace
insert. In such an event, make sure that in the room no under-pressure occurs compared with
the outdoor environment.
16.
15. CONNECTION TO THE CHIMNEY
Before connecting the freplace insert to the chimney, check the size and condition of
the chimney (according to the dIn 18160 directives and standards). The correct operation
of the chimney according to dIn En 13384 must be signed by legal authority. When making
the chimney calculations, you must include the parameters of the freplace insert. When
the door is open (when adding wood) a safer quantity of air and combustion gases are
taken away than during normal operation.
The fue channels must not be reduced to smaller diameters.
-
More than one heat source may be connected to one chimney only if the heat source is
equipped with self-closing door mechanism and is certifed according to En 13229 A1.
Consequently, the calculation must be according to the standard dIn En 13384, paragraph2.
Follow standards En 73 4201, dIn 18160, dIn 18896 or the regulations for this type of
consumer appliance in the country of installation.
Connection / chimney flue
-
the flap has holes in the net section of at least 3 % of the size of the total cross-section of the
flap, however, a minimum of 20 cm2.
21
- To supply air, it is recommended to use the shortest possible route and to deviate from
the direction of the line only if strictly necessary.
- Use work diagrams (see the professional regulations for fireplace specialists - Tr-ol) and
determine the cross-section of the air supply line.
- The air supply line must be from fireproofed form stable material.
- remove the insulation from the air supply line to prevent condensation.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.Caminetti Crystal at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.Caminetti Crystal in the language / languages: English as an attachment in your email.

The manual is 16.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info