kground
theme_color_case string[7] 1/6 Frame color
Group: ircutcontrol
NAME VALUE SECURITY
(get/set)
DESCRIPTION
mode auto,
day,
night,
schedule
6/6 Indicate which mode IR cut control
uses
“auto” means detecting day/night
automatically.
“day” means day mode.
“night” means night mode.
“schedule” means switching
day/night by schedule.
daymodebegintime <hh:mm> 6/6 Begin time of day mode
daymodeendtime <hh:mm> 6/6 End time of day mode
disableirled <boolean> 6/6 Disable IR illuminator
bwmode <boolean> 6/6 Switch to B/W in night mode
sensitivity high,
normal,
low
6/6 The sensitivity to detect it is night
mode
Drive the digital output
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0, 1. “0” means inactive or normal state while “1” means active or
triggered state.
PARAMETER VALUE DESCRIPTION
0 – inactive, normal state
do<num>
0, 1
1 – active, triggered state